Bluetooth Digital Multimeter

Features

-

Industrial,HVAC& Solar PV Application

-

High-Frequency Rejection

-

Loz for preventing false reading from ghost voltage

-

Auto Volt for automatic AC/DC voltage selection

-

Data Logging / Manual Save up to 4000 records

-

Battery Capacity indication in segments

Bluetooth Digital Multimeter

Features

-

Industrial,HVAC& Solar PV Application

-

High-Frequency Rejection

-

Loz for preventing false reading from ghost voltage

-

Auto Volt for automatic AC/DC voltage selection

-

Data Logging / Manual Save up to 4000 records

-

Battery Capacity indication in segments

Function

Range

OL Reading

Resolution

Accuracy

DC mV

600.0mV

660.0mV

0.1mV

±(0.5% + 5D)

DC Voltage

6.000V

6.600V

0.001V

±(0.5% + 2D)

60.00V

66.00V

0.01V

600.0V

660.0V

0.1V

1000V

1100V

1V

AC Voltage

600.0V

660.0V

0.1mV

±(1.0% + 3D)

6.000V

6.600V

0.001V

60.00V

66.00V

0.01V

600.0V

660.0V

0.1V

1000V

1100V

1V

PV DC Voltage

600.0V

660.0V

0.1V

±(2.0% + 5D)

2000V

2200V

1V

PV AC Voltage

600.0V

660.0V

0.1V

±(2.0% + 5D)

1500V

1600V

1V

DC Current

6.000A

6.600A

0.001A

±(1.0% + 3D)

10.00A

20.00A

0.01A

AC Current

6.000A

6.600A

0.001A

±(1.5% + 3D)

10.00A

20.00A

0.01A

Resistance

600.0Ω

660.0Ω

0.1Ω

±(0.9% + 5D)

6.000Ω

6.600Ω

0.001kΩ

±(0.9% + 2D)

60.00Ω

66.00Ω

0.00Ω

±(0.9% + 2D)

600.0Ω

660.0Ω

0.1kΩ

±(0.9% + 2D)

6.000Ω

6.600Ω

0.001MΩ

±(0.9% + 2D)

40.00MΩ

44.00MΩ

0.01MΩ

±(1.5% + 5D)

Continuity

600.0Ω

660.0Ω

0.1Ω

±(0.9% + 5D)

Diode

1.500V

1.550V

0.001V

±(0.9% + 2D)

Capacitance

1.000μF

1.100μF

0.001μF

±(1.9% + 5D)

10.00μF

11.00μF

0.01μF

±(1.9% + 2D)

100.0μF

110.0μF

0.1μF

1.000mF

1.100mF

0.001mF

10.00mF

11.00mF

0.01mF

Frequency

100.00Hz

100.00Hz

0.01Hz

±(0.1% + 2D)

1000.0Hz

1000.0Hz

0.1Hz

10.000kHz

10.000kHz

0.001kHz

100.00kHz

100.00kHz

0.01kHz

Temperature

-40.0°C – 400.0°C

440.0°C

0.1°C

±(1% + 20D)

-40.0°F – 752.0°F

824.0°F

0.1°F

±(1% + 36D)