您的瀏覽器不支援JavaScript功能, 若網頁功能無法正常使用時,請開啟瀏覽器JavaScript狀態 (Your browser does not support Javascript. For full functionality of this site, please enable JavaScript in your browser.)
To provide a better user experience, this website uses technical and analytics cookies. For related personal data rights and interests, please refer to the company's privacy policy area.
I agree
DETELUX 360FC 2CH PRO 110V
Movements
Home
ENERGY SAVING
Movements
DETELUX 360FC 2CH PRO 110V
Features
-
Downlight format for installations in false ceilings
-
360º detection coverage
-
Lux and time adjustement for channel 1 (lighting) and time adjustment for channel 2 (Ventilating)
-
Pulse output could be selected for channel 1 in order to connect the detector to a staircase timer
-
According to EN 60669-2-1:2004
Features
-
Downlight format for installations in false ceilings
-
360º detection coverage
-
Lux and time adjustement for channel 1 (lighting) and time adjustment for channel 2 (Ventilating)
-
Pulse output could be selected for channel 1 in order to connect the detector to a staircase timer
-
According to EN 60669-2-1:2004
DETELUX 360FC 2CH PRO 110V
DETELUX 360FC 2CH PRO 220V
Installation
False ceiling
False ceiling
Power supply
110-130V AC, 50/60Hz
220-240V AC, 50/60Hz
Connection
3-wire
3-wire
Technology
Infrared
Infrared
Coverage area
360º
360º
Range
6m diameter (at 2.2m)
6m diameter (at 2.2m)
Installation height
2.2m - 4m
2.2m - 4m
Time setting
CH1: 10s - 30min (Pulse option)
CH2: 10s - 60min
CH1: 10s - 30min (Pulse option)
CH2: 10s - 60min
Twilight adjustment
3lux - 2000lux (only CH1)
3lux - 2000lux (only CH1)
Relay Technology
Zero Cross Switching
Zero Cross Switching
Protection degree
IP20
IP20
Contact capacity
Channel 1: Incandescence: 800W
Energy saving and LED lamps: 200W
Channel 2: Load: 500W
Channel 1: Incandescence: 1200W
Energy saving and LED lamps: 300W
Channel 2: Load: 800W